Back to Top

1
Hi, Guest!
  • AEMC AEMC
  • AEMC AC/DC Current Probe Model MR416 (Replaces Cat #1200.68 - Model MR

AEMC AC/DC Current Probe Model MR416 (Replaces Cat #1200.68 - Model MR

Update Terakhir
:
21 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail AEMC AC/DC Current Probe Model MR416 (Replaces Cat #1200.68 - Model MR

Alat Laboratorium Mikrobiologi

Deskripsi produk
AC/DC Current Probe Model MR416 (Replaces Cat #1200.68 - Model MR411)
The MR416 is a hall effect current probe with 2 ranges designed for DMM and Data loggers. The probe has a 5 ft (1.5m) lead terminated by 4mm safety banana plugs and can measures up to 400AAC and 600ADC. The probe is powered by a 9V battery or by a standard 5V external power supply via a micro-USB connector (not supplied).

The instrument's design includes internal temperature compensation.

Specifications:

Maximum Conductor Size
Cables: One 1.18” (30mm) or two .94” (24mm)
Bus Bar: One 1.97 x .39” (50 x 10mm) or two 1.23 x .39” (31.5 x 10mm) or three 0.98” x 0.31” (25 x 8mm)
Current Range
0.5 to 40AAC, 60ADC & 0.5 to 400AAC, 600ADC
Output Signal
10mV/A & 1mV/A via a 5ft (1.5m) lead with 4 mm safety banana plug
Accuracy 50/60Hz
≤1.5% @ 40A & ≤2% @ 400A
Frequency Range
DC to 30kHz (-3dB) (depending of current value)
Phase Shift At 50Hz
≤2.2°@ 40A ≤1.5° @ 400A
Load Impedance
>1MΩ and ≤100pF
Overload
3000ADC or 1000AAC continuous for < 1kHz
Zero Adjust
Automatic on both ranges
Power Supply
9V alkaline Battery (NEDA 1060A, 6LR61) or 5V DC Micro-USB type B
Battery Life
50H typical
Low Battery Indication
Green LED blinking
Overload Indication
Red LED on when measurement > than selected range
Dimensions (H x W x D)
8.82 x 3.82 x 1.73” (224 x 97 x 44mm)
Weight (with Battery)
0.98lbs (440g)
Operating Temperature
14° to +131°F (-10 to +55°C)
Storage Temperature
-40° to +176°F (-40 to +80°C)
Relative Humidity
Up to 85% @ 35°C
Ingress Protection (Ip)
IP 40
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600V CAT III
Maximum Conductor Size
Cables: One 1.18” (30mm) or two .94” (24mm)
Bus Bar: One 1.97 x .39” (50 x 10mm) or two 1.23 x .39” (31.5 x 10mm) or three 0.98” x 0.31” (25 x 8mm)
Current Range
0.5 to 40AAC, 60ADC & 0.5 to 400AAC, 600ADC
Output Signal
10mV/A & 1mV/A via a 5ft (1.5m) lead with 4 mm safety banana plug
Accuracy 50/60Hz
≤1.5% @ 40A & ≤2% @ 400A
Frequency Range
DC to 30kHz (-3dB) (depending of current value)
Phase Shift At 50Hz
≤2.2°@ 40A ≤1.5° @ 400A
Load Impedance
>1MΩ and ≤100pF
Overload
3000ADC or 1000AAC continuous for < 1kHz
Zero Adjust
Automatic on both ranges
Power Supply
9V alkaline Battery (NEDA 1060A, 6LR61) or 5V DC Micro-USB type B
Battery Life
50H typical
Low Battery Indication
Green LED blinking
Overload Indication
Red LED on when measurement > than selected range
Dimensions (H x W x D)
8.82 x 3.82 x 1.73” (224 x 97 x 44mm)
Weight (with Battery)
0.98lbs (440g)
Operating Temperature
14° to +131°F (-10 to +55°C)
Storage Temperature
-40° to +176°F (-40 to +80°C)
Relative Humidity
Up to 85% @ 35°C
Ingress Protection (Ip)
IP 40
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600V CAT III

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208
Tampilkan Lebih Banyak
Kontak Kami