Deskripsi produk
AmpFlex® Flexible Sensors
The AmpFlex® is an AC current sensor composed of a flexible Rogowski coil and an electronic module. The sensor permits measurements on conductors where standard clamp-on probes cannot be used. In particular, it can be installed in tight spaces, around cable bundles, around wide or large bus bars, or even wrapped around irregular shapes. The Shape Memory feature enables the user to pre-shape the sensor before inserting it between or around conductors. This feature facilitates positioning the sensor around the conductor, enhances user safety, and alleviates the drooping effect associated with other flexible sensors.

The AmpFlex® has a mV output proportional to the current measured for direct readings on DMMs, loggers, oscilloscopes and power or harmonic meters. The length of the flexible sensor can be selected from 24" (450mm) to 60" (1520mm).

NOTE: AmpFlex ranges/lengths can be customized as special orders. Contact customer service for price and lead-time.

Specifications :

Model # 300-24-2-10 (Cat. #2112.88)
Maximum Conductor Size
8" (190mm)
Current Range
30 and 300Arms AC
Measurement Range
5 to 300A
Output Signal
100mV/A and 10mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
1.3°
Model # 1000-24-1-1 (Cat. # 2112.39)
Maximum Conductor Size
8" (190mm)
Current Range
1000Arms AC
Measurement Range
5 to 1000A
Output Signal
100mV/A and 10mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.7°
Model # 1000-24-2-1 (Cat. # 2112.98)
Maximum Conductor Size
8" (190mm)
Current Range
100 and 1000A rms AC
Measurement Range
5 to 1000A
Output Signal
10mV/A and 1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.7°
Model # 1000-36-2-1 (Cat. # 2113.00)
Maximum Conductor Size
11" (290mm)
Current Range
100 and 1000Arms AC
Measurement Range
5 to 1000A
Output Signal
10mV/A and 1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.5°
Model # 3000-24-1-1 (Cat. # 2112.46)
Maximum Conductor Size
8" (190mm)
Current Range
3000A rms AC
Measurement Range
5 to 3000A
Output Signal
1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.7°
Model # 3000-24-2-1 (Cat. # 2113.05)
Maximum Conductor Size
8" (190mm)
Current Range
300 and 3000A rms AC
Measurement Range
5 to 3000A
Output Signal
10mV/A and 1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.5°
Model # 3000-36-1-1 (Cat. # 2112.48)
Maximum Conductor Size
1" (290mm)
Current Range
3000Arms AC
Measurement Range
5 to 3000A
Output Signal
1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.5°
Model # 3000-36-2-1 (Cat. # 2112.00)
Maximum Conductor Size
11" (290mm)
Current Range
300 and 3000Arms AC
Measurement Range
5 to 3000A
Output Signal
10mV/A and 1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.5°
Model # 3000-48-2-1 (Cat. # 2112.01)
Maximum Conductor Size
15" (390mm)
Current Range
300 and 3000Arms AC
Measurement Range
5 to 3000A
Output Signal
10mV/A and 1mV/A
Accuracy
1% ± 200mA
Phase at 50Hz
0.5°
Model # 6000-36-2-1 (Cat. # 2113.21)
Maximum Conductor Size
11" (290mm)
Current Range
600 and 6000Arms AC
Measurement Range
5 to 6000A
Output Signal
1mV/A and 0.1mV/A
Accuracy
1% ± 500mA
Phase at 50Hz
0.5°
Model # 30000-24-2-0.1 (Cat. # 2113.33)
Maximum Conductor Size
8" (190mm)
Current Range
3000 and 30000Arms AC
Measurement Range
5 to 30000A
Output Signal
1mV/A and 0.1mV/A
Accuracy
1% ± 1A
Phase at 50Hz
0.5°
General Specifications

Frequency Range
10Hz to 20KHz
Battery Type
9V Alkaline, Type LF22
Battery Life
>150 hours continuous
Operating Temperature
14° to +131°F (-10° to +55°C)
Storage Temperature
-40° to +158°F (-40° to +70°C)
Operating Humidity
90% up to 104°F (40°C),
Ampflex® Sensor
The flexible sensor can withhold a temperature of 194°F (90°C) and is resistant to oil and Aliphatic hydrocarbons
Cable Length (Module to Sensor
6.5ft (2m)
Battery Indicator
Green LED blink when battery needs replacement
Overload
Red LED ON when output around >4.5V
Dimensions (H x W x D)
Module: 4.9 x 2.5 x 1.1” (124 x 64 x 28mm)
Weight with 24” (610mm) Sensor
0.74 lb (336g)
Pollution Degree
2
Ingress Protection (IP)
IP65 sensor and IP40 electronic module
EMC
EN 61326-1
Safety Compliance
EN/IEC 61010-1 600V CAT IV, 1000V CAT III
EN/IEC 61010-032:2002

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208
Tampilkan Lebih Banyak
Kontak Kami