Back to Top

1
Hi, Guest!

AEMC Data Logger Model L452

Update Terakhir
:
21 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : [email protected]

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail AEMC Data Logger Model L452

Alat Laboratorium Mikrobiologi

Deskripsi produk
Data Logger Model L452
The Model L452 is a low cost, simple to use, two-channel data logger. It records DC voltage, DC current, pulses and events. Its two input channels allow the user to connect to various types of sensors in order to record data such as pressure, temperature, flow, humidity and more. This logger can also be used to record events such as machine run time. Each channel's real-time measurement is displayed on the LCD screen. The L452 communicates via USB or Bluetooth for configuration and data transfer to a PC using the free DataView software included with the unit. The logger can also be configured using its front panel with a very simple user interface.

Specifications :

Channels
Two with LCD display
Input
4mm safety banana jacks
Ranges (4)
100mV/1V/10V, 4 to 20mA, Event & Pulse
Accuracy
± 100mV, ±1V, ±10V: ±(0.5% R +1ct)

4 to 20mA ±(0.25% R +5ct)
Resolution
Pulse: 3.3V (with 1MΩ pull up resistor)

Event: ± 10V
Input Impedance
V DC: 1MΩ, DC current: 100Ω Event: 1MΩ, Pulse N/A
Sample Rate Max
V & Current DC: 5 samples/s, Event 16 samples/s, Pulse 100 samples/s
Storage Rate
Programmable from 200 ms to 60 minutes
Storage Modes
Start/Stop
Recording Length
15 minutes to 6 weeks, programmable using DataView
Memory
32MB recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.
Communication
USB 2.0, Bluetooth 2.1 Class 1 (100m)
Power Source
2x1.2V 400mAh NIMH
Charger (Supply)
Rechargeable by main 110 to 240V 50/60Hz or via USB cable
Battery Life (Display ON)
18 days @ 200ms sampling rate, 27 days @ 60s
Battery Life (Display OFF)
36 days @ 200ms sampling rate, 270 days @ 60s
Dimensions
4.92 x 2.60 x 1.30” (125 x 66 x 33mm)
Weight (with battery)
7.4 oz (210g)
Case
Polycarbonate
Operating Temperature
32° to 122°F (0° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 65°C)
Relative Humidity
Up to 90% @ 104°F (40°C)
Ingress Protection (IP)
IP40
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-30

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208