Detail AEMC Digital Transformer Turns Ratiometer Model 8510

Alat Laboratorium Mikrobiologi

Deskripsi produk
Digital Transformer Turns Ratiometer Model 8510
The DTR® Model 8510 is an easy-to-use portable digital transformer turns ratiometer designed for on-site testing of power, potential and current transformers. When connected to a non-energized transformer, the DTR® Model 8510 accurately measures primary to secondary turns ratio, while simultaneously displaying polarity and excitation current.

The DTR® is fully automatic and uses an ANSI/IEEE compliant test method. No user calibration, range selection, hand cranking or tedious balancing is required. At each measurement, the DTR® automatically self-calibrates and checks for open windings/connections/circuit breakers, short circuits (excess excitation current), incorrect test lead placement, and reverse polarity. Measurements are displayed quickly and accurately.

Specifications:Deskripsi produk
Digital Transformer Turns Ratiometer Model 8510
The DTR® Model 8510 is an easy-to-use portable digital transformer turns ratiometer designed for on-site testing of power, potential and current transformers. When connected to a non-energized transformer, the DTR® Model 8510 accurately measures primary to secondary turns ratio, while simultaneously displaying polarity and excitation current.

The DTR® is fully automatic and uses an ANSI/IEEE compliant test method. No user calibration, range selection, hand cranking or tedious balancing is required. At each measurement, the DTR® automatically self-calibrates and checks for open windings/connections/circuit breakers, short circuits (excess excitation current), incorrect test lead placement, and reverse polarity. Measurements are displayed quickly and accurately.

Specifications:

VT/PT Ratio Range
Auto-Ranging: 0.8000:1 to 8000.0:1
VT/PT Accuracy
0.8000 to 9.9999: ±0.2% of Reading
10.000 to 999.99: ±0.1% of Reading
1000.0 to 4999.9: ±0.2% of Reading
5000.0 to 8000.0: ±0.25% of Reading
CT Ratio Range
Auto-Ranging: 0.8000 to 1000.0
CT Accuracy
±0.5% of Reading
Excitation Signal
VT/PT Mode: 32Vrms max
CT Mode: Auto Level 0 to 1A, 0.1 to 4.5Vrms
Excitation Current Display
Range: 0 to 1000mA
Accuracy: ±(2% of Reading +2mA)
Excitation Frequency
70Hz
Display
LCD 16 character, 2 line, large format, LED backlight, day/night visible
Languages Supported
English, Spanish, French, Italian, German, Portuguese
Communication
Optically isolated USB 2.0
Data Storage
Up to 10,000 complete measurements
Power Source
Two rechargeable 12V NiMH batteries (included)
Battery Life
Up to 10 hours of continuous operation
Low Battery Indication
LED and LCD
External Charger
90 to 240V, 50/60Hz (smart charger)
Charging Time
<4 hours
Measurement Method
In accordance with ANSI/IEEE Std. C57.12.90-2006
Software
DataView analysis software included
Dimensions
10.70 x 9.76 x 5.12” (272 x 248 x 130mm)
Weight
8.1 lbs (3.7kg)
Operation Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Index of Protection
IP40 (lid open), IP53 (lid closed)
Double Insulated
Yes
CE Approved
Yes
Safety Compliance
IEC 61010-1 (1995-A2) 50V CAT IV Pollution 2


VT/PT Ratio Range
Auto-Ranging: 0.8000:1 to 8000.0:1
VT/PT Accuracy
0.8000 to 9.9999: ±0.2% of Reading
10.000 to 999.99: ±0.1% of Reading
1000.0 to 4999.9: ±0.2% of Reading
5000.0 to 8000.0: ±0.25% of Reading
CT Ratio Range
Auto-Ranging: 0.8000 to 1000.0
CT Accuracy
±0.5% of Reading
Excitation Signal
VT/PT Mode: 32Vrms max
CT Mode: Auto Level 0 to 1A, 0.1 to 4.5Vrms
Excitation Current Display
Range: 0 to 1000mA
Accuracy: ±(2% of Reading +2mA)
Excitation Frequency
70Hz
Display
LCD 16 character, 2 line, large format, LED backlight, day/night visible
Languages Supported
English, Spanish, French, Italian, German, Portuguese
Communication
Optically isolated USB 2.0
Data Storage
Up to 10,000 complete measurements
Power Source
Two rechargeable 12V NiMH batteries (included)
Battery Life
Up to 10 hours of continuous operation
Low Battery Indication
LED and LCD
External Charger
90 to 240V, 50/60Hz (smart charger)
Charging Time
<4 hours
Measurement Method
In accordance with ANSI/IEEE Std. C57.12.90-2006
Software
DataView analysis software included
Dimensions
10.70 x 9.76 x 5.12” (272 x 248 x 130mm)
Weight
8.1 lbs (3.7kg)
Operation Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Index of Protection
IP40 (lid open), IP53 (lid closed)
Double Insulated
Yes
CE Approved
Yes
Safety Compliance
IEC 61010-1 (1995-A2) 50V CAT IV Pollution 2





Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208











Tampilkan Lebih Banyak
Kontak Kami