Back to Top

1
Hi, Guest!
  • AEMC AEMC
  • AEMC Power & Energy Logger Model PEL 105

AEMC Power & Energy Logger Model PEL 105

Update Terakhir
:
20 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail AEMC Power & Energy Logger Model PEL 105

Alat Laboratorium Mikrobiologi

Deskripsi produk
Power & Energy Logger Model PEL 105
AEMC’s Model PEL 105 is a simple to use, power and energy data logger that monitors both traditional and renewable energy sources. It monitors and records True RMS voltage and current, power, energy, cost and harmonics locally or from anywhere in the world. The PEL 105 is built into a waterproof case with an IP67 rating designed for outdoor use and is ideal for pole mounting and can be powered from a phase being monitored. This product is perfect for electricians, engineers and contractors doing work in the areas of building and system monitoring and upgrades, including compliance to article 220.87 of the NEC, as well as overall energy audits and incoming power monitoring. It is available with an Android™ App to configure, view and capture data wirelessly. Bluetooth and Wi-Fi wireless communication provides the operator with the ability to work from a safe distance away from dangerous voltages and currents.
Specifications :

nputs
5 Voltage / 4 Current
Sample Rate
128 per Cycle
6.4kHz at 50Hz
7.68kHz at 60Hz
Specification
Range
Measurement Range
Resolution
Accuracy (Typical)
Volt
Vrms
1000V P to N
10 to 1000V
0.1V
±0.2% Rdg +0.2V
Vrms
1000V E to N
10 to 1000V
0.1V
±0.2% Rdg +0.2V
Urms
1000V P to P
17 to 1000V
0.1V
±0.2% Rdg + 0.4V
Amps @ 50 and 60Hz
Amps (1V nominal)
(excluding clamp accuracy
Probe dependent
0.2%< I < 120% Inom
Probe dependent
±0.2% Rdg + 0.02% Inom
AmpFLEX & MiniFlex
(including sensor accuracy)
Range 100A
Range 400A
Range 2kA
Range 10kA
200mA to 120A
5 to 440A
50 to 2400A
400A to 12kA
1mA
0.1A
0.1A & 1A
1A
±1.2% Rdg + 50mA
±1.2% Rdg + 0.2A
±1.2% Rdg + 1A
±1.2% Rdg + 5A
Frequency

42.5 to 69Hz
0.01Hz
±0.1Hz
Power
Watts (VA, var) P-Q-S
20W to 20GW / 20var to 10Gvar / 20VA to 10GVA
4 digits min
±0.5% Rdg + 0.005% Pnom
Power Factor (Cos Φ/DPF)
-1 to 1
0.001
±0.05
Energy
kWh (kVAh, kvarh) P-Q-S
Up to 4EWh / 4Evarh / 4 EVAh (E = 1018 )
±0.5% Rdg
Harmonics
DC, 1 to 50
Volts & Amp %

0.01 to 655.0%
0.01%
±1% Rdg from 1 to 25
THD

0.00 to 655.0%
0.01%
±1% Rdg
General Features
Case
Design Rugged field case
Interface
Isolated USB, Bluetooth, and Ethernet, Wi-Fi, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included
Memory
8GB SD card (SDHC compliant, FAT32 formatted) 32GB max
Display
LCD with backlight 4.2 x 3.3” (107 x 84mm)
Real-Time Clock
Time and date stamp for Trend mode
Power
Phase to phase or phase to neutral 100 to 1000VAC or external power pack 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical
Dimensions (L x W x H)
9.65 x 10.6 x 7.1” (245 x 270 x 180mm)
Weight
8.9 lbs (4kg)
Altitude Operating
2000m (6560ft)
Operating Temperature
32° to 108.5°F; (0° to +42.5°C) from 10 to 85% RH
Storage Temperature
-4° to 122°F; (-20° to +50°C) from 0 to 75% RH with battery pack
Electro-Magnetic-Compatibility (EMC)
EN 61326-1 for emission and immunity
IP Rating
IP 67 per IEC 60529
Safety
IEC/EN 61010-1 (1000V CAT IV Pol 4)

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208
Tampilkan Lebih Banyak
Kontak Kami