Back to Top

1
Hi, Guest!
  • AEMC AEMC
  • AEMC Simple Logger® II Model AL834

AEMC Simple Logger® II Model AL834

Update Terakhir
:
21 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail AEMC Simple Logger® II Model AL834

Alat Laboratorium Mikrobiologi

Deskripsi produk
Simple Logger® II Model AL834
The Simple Logger® II Bluetooth Edition Model AL834 is a 4-channel AC current data logger with four integral flexible current sensors. Each sensor is 24 inches long and capable of wrapping around an 8 inch conductor. The AL834 has two measurement ranges of up to 300 and 3000 Amps. Both the data logger housing and the current sensors are water resistant rated to IP 65. A selection of data storage modes, as well as data sampling rates is user programmable through the free DataView® software included with the unit. Up to 1,000,000 measurements can be stored in internal nonvolatile memory. Data storage rates as fast as 8 per second are user programmable.

Specifications :

Channels
Four
Input
Captive AmpFlex® AC current flexible sensors
Ranges (2)
300AAC
3000AAC
Accuracy (50/60Hz)
5 to 300A ± (1% Rdg +0.5A)
15 to 3000A (1% Rdg +1A)
Resolution
0.1AAC
0.5AAC
Sample Rate
64 samples / cycle
Storage Rate
Programmable from 125ms to 1 per day
Storage Modes
Start/Stop, FIFO, extended mode (XRM) and Alarm
Recording Length
15 minutes to 8 weeks, programmable using DataView
Memory
1,000,000 measurements (2MB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.
Communication
Bluetooth (class 2 )
Power Source
4x1.5V C alkaline batteries
Battery Life
>200 hours at 125ms up to to >180 days (depending of sample rate/recording length)
Dimensions
5.9 x 5.9 x 3.57” (150 x 150 x 91mm)
Weight (With Battery)
3.9 lbs (1.77kg)
Case
UL94-V0 / Case UL94-5VB
Operating Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Relative Humidity
Up to 85% @ 95°F (35°C) non condensing
Ingress Protection (IP)
IP65 (Cover closed)
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-32 600V CAT IV; Pollution Degree 2

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208
Tampilkan Lebih Banyak
Kontak Kami