Detail AEMC Simple Logger® II Model L562

Alat Laboratorium Mikrobiologi

Deskripsi produk
Simple Logger® II Model L562
The Simple Logger® II Model L562 is a two channel Volt/Amp data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode XRMTM and delayed start time are just two of the many application friendly features. The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the inputs are ignored between measurement intervals.

NOTE: There are many compatible current probes available as an accessory. The following current probes will also need the Adapter Cat. #2118.46 which is sold separately:
MF 300-6-2-10 | 300-24-2-1 | 1000-24-1-1 | 1000-24-2-1 | 1000-36-2-1 | 6000-36-2-0.1 | 30000-24-2-0.1 | MN01 | MN02 | MN03 | MN251 | MN255 | MN353 | MN373 | MN375 | MN379 | SR661 | SR752 | SR759
Specifications :

Channels
Two
Connection
Current Channel
Voltage channel
Input
BNC
4 mm safety banana jacks
Ranges (2)
0 to 1 V for use with current probe with mV output
5 to 600 VAC
Accuracy (50/60Hz)
(10 to 50) mV: ±(0.5% R +1mV)
(50 to 1000) mV ±(0.5% R +0.5mV)
(5 to 50) V: ±(0.5% R +1V)
(50 to 600) V: (0.5% R +0.5V)
Resolution
0.1 mVAC
0.1 VAC
Maximum Input Voltage
5 rms or ±7.07 VPeak
1.2 x 600 Vrms or 720 Vrms
Input Impedance
800 kΩ
40 MΩ
Sample Rate
64 samples / cycle
Storage Rate
Programmable from 125 ms to 1 per day
Storage Modes
Start/Stop, FIFO, extended mode (XRM) and Alarm
Recording Length
15 minutes to 6 weeks, programmable using DataView
Memory
240,000 measurements (512 kB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.
Communication
USB 2.0 optically isolated
Power Source
(2) 1.5 V AA (LR6) alkaline batteries
Battery Life
100 h to >45 d (depending on sample rate/recording length)
Dimensions
(4.94 x 2.75 x 1.28) in / (125 x 70 x 32) mm
Weight (with Battery)
6.4 oz (180 g)
Case
Polycarbonate
Operating Temperature
(14 to 122) °F (-10 to 50) °C
Storage Temperature
(-4 to 140) °F (-20 to 60) °C
Relative Humidity
Up to 85 % @ 95 °F (35)°C
Ingress Protection (IP)
IP40
EMC
EN 61326-1
Safety Compliance
IEC 61010-1, EN 61010-2-32 600V CAT III Pollution Degree 2