Back to Top

1
Hi, Guest!

Automatic Cleveland Open Cup Flash Point Tester DISSOLUTION TESTER

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Automatic Cleveland Open Cup Flash Point Tester DISSOLUTION TESTER

Automatic Cleveland Open Cup Flash Point Tester

For flash and fire point of all petroleum products, except fuel oils and those having an open cup flash below 79°C (175°F)
  • Conforms to ASTM D92 and related specifications
  • Simple automation routine for easy operation
  • Flash point operation between ambient and 400°C
  • Flash and Fire Point detection by Ionization Ring
  • Gas or electric ignition
  • Data Storage: 200 results
  • Automatic gas cut-off at the end of the test
  • Equipped with Emergency Safety Switch
The automated Cleveland Open Cup flash point tester accurately determines flash and fire point temperatures of viscous petroleum products including oils and bitumens over an extended temperature range. When examining highly viscous specimens, a preheating time and temperature are set in order to liquefy the sample for testing. The surface skin from bituminous samples can be removed with a skimmer. The flash/fire point tests are simply conducted by mounting the flash cup filled with sample into the test position and selecting a pre-programmed test method or the search mode to determine an approximate flash point. The test results are automatically corrected to standard pressure (101.3 kPa). Equipped with a differential Pt-100 RTD probe, the system is designed to duplicate the response time of a mercury-in-glass thermometer. Multiple sensors continually monitor instrument function, displaying an error message if a problem is detected. The performance of the ionization sensor which detects the flash and fire points is continuously monitored, and the user is notified upon the need of replacement. If a flash is not detected 20°C above the expected flash point or at 420°C, then the test is automatically aborted for safety. The system is easily interfaced with an external PC for operation and method updates. When performing a test, the system will display the stirring speed, temperature curve (also printed out), and current test status. The system alerts the user if the first application of the ignitor results in a flash or if no flash point is detected at the end of the test program. If a flash is not detected 30°C above the expected flash point or at 400°C, then the test is automatically aborted for safety.

  • Ticket Printer
  • Test Cup
  • PT100 Probe
  • Detection Cable
  • Gas Tubing
  • RS232C Output
  • Data Acquisition Software
  • Conforms to the specifications of: ASTM D92; IP 36, 403; ISO 2592; AFNOR T60-118; EN 22592; DIN 51376

115V 60Hz 1000W
230V 50Hz 1000W

lxwxh,in.(cm): 21x10.5x19.75(53.5x26x50)

Net Weight: 53 lbs (24 kg)

Shipping Weight: 91 lbs (41.3 kg)

 

Dimensions: 29x20x27 in. (73.7x50.8x68.6 cm)