Back to Top

1
Hi, Guest!

Automatic Low Temperature Filterability Test Alat Pengukur Suhu

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Automatic Low Temperature Filterability Test Alat Pengukur Suhu

Automatic Low Temperature Filterability Test

KLA-7 Automatic low temperature filterability test analyzer (LTFT)115V/60 HZ

KLA-7(220) Automatic low temperature filterability test analyzer (LTFT)22OV 50/60HZ

Determines the filterability of Diesel fuels and Biodiesel blend fuels in some automotive equipment at low temperatures. The Low Temperature Flow Test results are indicative of the low temperature flow performance of the test fuel in some diesel vehicles. The test method is especially useful for the evaluation of fuels containing flow improver additives in a range of +10°C to -30°C.

Up to (6) 300 ml test vessels are cooled at a specified rate of 1°C/h, and at every °C of cooling, a vacuum of 20 kPa is applied to a filter assembly immersed in the first sample. If the sample recovered in a graduated receiver vessel reaches the 180 ml in 60 sec., the analysis continues to the further 1°C test temperature (passed). When the sample doesn't reach the 180 ml within the 60 sec., the test is failed. The temperature of the last passing result test has to be recorded as minimum LTFT pass temperature. The instrument is a six place floor model, equipped with a built in cooling system with a single stage CFC free motor compressor for temperatures as low as -45°C. Integrated Vacuum System consisting of a 350 kPa micropump, vacuum stabilizer and electronic control for vacuum regulation of 20 kPa. Fully automatic, controlled by an integrated panel pc with touch screen and a large display. All the parameters and the current status of the analysis are shown in real time.

Conforms to the Specifications of: ASTM D4539

Temperature Range: +80°C to -80°C

Resolution: 0.06°C

Accuracy: ±0.1°C

Repeatability / Reproducibility: Meets or exceeds ASTM specifications

Storage Capacity: Up to 60,000 analyses

Interface: USB Port (2)115V ±15%, 60Hz
220V ±15%, 50/60Hz

wxdxh,in.(cm): 38 1⁄2 x 23 1⁄2 x 51 1⁄4 (98x60x130)
Net Weight: 176.5 lbs (80kg)

  • KLA-PT100-CAL Calibration Box and Cables
  • KLA-DB-KIT Kit of Connectors and Cables for Cold range
Tampilkan Lebih Banyak
Kontak Kami