Back to Top

1
Hi, Guest!
  • 3nh 3nh
  • Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)

Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)

Update Terakhir
:
16 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)

Alat Laboratorium Mikrobiologi

Spesifikasi Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)
Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)

Catalog Number
Size
Approximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
without holders
with round metal holders*
with rectangular metal holders**
Low
High
Standard
Unity Factor
Standard
Unity Factor
Standard
Unity Factor
9723-S50
9723-U50
9723-W50
9721-Y50
9724-B50
9724-D50
1
0.003
0.6
2.0
9723-S53
9723-U53
9723-W53
9723-Y53
9724-B53
9724-D53
2
0.01
2.0
10
9723-S56
9723-U56
9723-W56
9723-Y56
9724-B56
9724-D56
3
0.03
6.0
30
9723-S59
9723-U59
9723-W59
9723-Y59
9724-B59
9724-D59
4
0.1
20
100
9723-S62
9723-U62
9723-W62
9723-Y62
9724-B62
9724-D62
5
0.3
60
300
9723-S65
9723-U65
9723-W65
9723-Y65
9724-B65
9724-D65
6
1.0
200
1000
9723-S68
9723-U68
9723-W68
9723-Y68
9724-B68
9724-D68
7
3.0
600
3000
9723-S71
9723-U71
9723-W71
9723-Y71
9724-B71
9724-D71
8
10
2000
10000
9723-S74
9723-U74
9723-W74
9723-Y74
9724-B74
9724-D74
9
30
6000
30000
9723-S77
9723-U77
9723-W77
9723-Y77
9724-B77
9724-D77
10
100
20000
100000
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
* round holder is compatible with a 51 mm (2 in) diameter port
** rectangular holder is compatible with a bath opening of 25 mm × 48 mm (1 in × 1.9 in)


The Zeitfuchs Cross-Arm Viscometer measures kinematic viscosity of transparent and opague Newtonian liquids according to ASTM D445 and ISO 3104. Filling and cleaning does not require removal from the constant temperature bath. Minimum sample volume is 1 to 3 mL. Minimum bath depth is 230 mm (9 in). Unity factor series has a constant within ± 0.2% of the values listed. Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round or rectangular metal holders are included or may be ordered separately.

Alat Laboratorium Umum
Harga Cannon - Zeitfuchs Cross-Arm Viscometer (Reversed Flow)
: CALL


Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-42803208

Tampilkan Lebih Banyak
Kontak Kami