DURAN® Measuring Cylinder with hexagonal base

DURAN® Measuring Cylinder

 

DURAN® Measuring cylinders are for holding measuring varying amounts of liquids. Available in two different accuracy classes – class “A” with main ring points graduation and class “B” with line graduation. For additional differentiation, the measuring cylinders with accuracy class ”A” have a blue graduation whereas the “B” class measuring cylinders a white graduation. Volume content tolerances for measuring and mixing cylinders conform to DIN and ISO accuracy limits.Thus the desired concentration can be precisely created.

Cat. No. Capacity
ml Accuracy limit
± ml Graduation divisions
ml h
mm d
mm Pack
Quantity
21 390 07 01 5 0,05 0,1 112 12 2
21 390 08 04 10 0,1 0,2 137 14 2
21 390 14 06 25 0,25 0,5 167 21 2
21 390 17 06 50 0,5 1 196 25 2
21 390 24 02 100 0,5 1 256 29 2
21 390 36 04 250 1 2 331 39 2
21 390 44 03 500 2,5 5 360 53 2
21 390 54 08 1000 5 10 460 65 1
21 390 63 01 2000 10 20 500 85 1
Tampilkan Lebih Banyak
pt andalan bangun sejahtera
pt andalan bangun sejahtera

PT ANDALAN BANGUN SEJAHTERA

Anggota PREMIUM 9 Tahun
JL. Sumur Batu No.1 RT.01 - RW.06 Kel.Sumur Batu - Kec.. Kemayoran, Jakarta Pusat
Indonesia 10640
Jakarta Pusat
15 / 11 / 2019
Hubungi Kami

Detail DURAN® Measuring Cylinder With Hexagonal Base Glassware

DURAN® Measuring Cylinder with hexagonal base

DURAN® Measuring Cylinder

 

DURAN® Measuring cylinders are for holding measuring varying amounts of liquids. Available in two different accuracy classes – class “A” with main ring points graduation and class “B” with line graduation. For additional differentiation, the measuring cylinders with accuracy class ”A” have a blue graduation whereas the “B” class measuring cylinders a white graduation. Volume content tolerances for measuring and mixing cylinders conform to DIN and ISO accuracy limits.Thus the desired concentration can be precisely created.

Cat. No. Capacity
ml Accuracy limit
± ml Graduation divisions
ml h
mm d
mm Pack
Quantity
21 390 07 01 5 0,05 0,1 112 12 2
21 390 08 04 10 0,1 0,2 137 14 2
21 390 14 06 25 0,25 0,5 167 21 2
21 390 17 06 50 0,5 1 196 25 2
21 390 24 02 100 0,5 1 256 29 2
21 390 36 04 250 1 2 331 39 2
21 390 44 03 500 2,5 5 360 53 2
21 390 54 08 1000 5 10 460 65 1
21 390 63 01 2000 10 20 500 85 1