Back to Top

1
Hi, Guest!
  • Haz Dust - Epam 5000, Environmental Particulate Air Monitor

Haz Dust - Epam 5000, Environmental Particulate Air Monitor

Update Terakhir
:
08 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Haz Dust - Epam 5000, Environmental Particulate Air Monitor

HAZ-DUST EPAM-5000 ENVIRONMENTAL PARTICULATE AIR MONITORS

Description

The HAZ-DUST EPAM-5000 is a portable microprocessorbased particulate monitor suitable for ambient, environmental, and indoor air quality investigations. Highly sensitive, this monitor uses light scattering to measure particle concentration and provide immediate real-time determinations and data recordings of airborne particle concentration in mg/m3 . Interchangeable size-selective impactors allow PM10, PM2.5, and PM1 monitoring; TSP measuring does not require an impactor. The EPAM-5000’s unique aerodynamic particle sizing and 47-mm in-line fi lter holder loaded with appropriate fi lter provide concurrent gravimetric sampling. Sample for up to 24 hours on one battery and store up to 15 months of monitoring data. Download and store sampling data on a PC for further analysis using included DustComm Professional Software. Trend analysis and reporting can also be generated. The EPAM-5000 offers a network software option for Windows and Apple.

• Fast, easy setup

• Highly sensitive and accurate

  - 0.001 to 20.0 mg/m3 for particles 0.1 to 100 μm

  - Optional 0.01 to 200 mg/m3 and 0.10 to 2000 mg/m3 ranges available

  - Accuracy ± 10% fi lter gravimetric SAE fi ne test dust

• High correlation to EPA PM10 methods and TEOM®

  - Ideal for saturation sampling

• Internal 1 to 4 L/min sample pump*

• Unique aerodynamic particle-sizing real-time sensor

  - Optional EPA FRM-style cassette holder for gravimetric reference

• Immediate display and data storage

• Internal temperature compensation for ambient use

• Interchangeable size-selective impactors for EPA parameters

  - PM10, PM2.5, and PM1.0; measures TSP without impactor

• Rechargeable lead-acid battery for up to 24-hour operation

  - Continuous monitoring with AC adapter

• Easy four-key menu driven operation

• Stores up to 15 months of data

  - RS232 digital output

• DustComm Pro data analysis/reporting software included

• Portable and compact

  - 14 x 6 x 10 inches (35.6 x 15.2 x 25.4 cm)

  - 10 pounds (4.5 kg)

• Real-time clock and data display

• Audible alarm siren

 

EPAM-5000 Features :

  • User-programmable start and stop time for unattended data collection
  • On-screen user-selectable sampling parameters retained in memory for quick, easy deployment when sampling parameters remain unchanged
  • Wireless data transmission option transmits data up to 5 miles
  • Improved DustComm Pro PC Software provides: - Greater fl exibility in graphical reports — create and label in new “draw and paint” program - Basic trend analysis - Live data feed and logging from wireless data transmission
  • Wireless network software option available for Windows and Apple

 

EPAM-5000 Applications

  • Quantifying off-site particulate migration
  • Surveying for PM2.5 and PM10
  • Monitoring dust generation during drilling and excavation
  • Evaluating dust suppression and engineering controls
  • Locating and identifying “hot spots”
  • Emergency response and fugitive emissions compliance
  • Determining level of respiratory protection
  • Survey of workplace for OSHA/EPA compliance
  • Evaluating worker exposure to airborne contaminants
  • Dust collector/ventilation system checks
  • Monitoring lung-damaging particles in factories and buildings
  • Complementary instrument for all EPA and OSHA personal and ambient particulate air sampling procedures 


Performance Profile

  • Sensing Range: 0.001 to 20 mg/m3 ; 0.01 to 200 mg/m3 (optional); 0.10 to 2000 mg/m3 (optional)
  • Particle Size Range: 0.1 to 100 μm
  • Precision: ± 0.003 mg/m3 (3 μg/m3 )
  • Accuracy: ± 10% filter gravimetric SAE fi ne test dust
  • Sampling Flow Rate: 1 to 4 L/min with variable adjustment
  • Filter Cassette Holder: 47 mm, FRM style 37-mm or 25-mm cassette (optional)
  • Alarm Output: 90 dB at 3 ft
  • Analog Output: 0 to 2 vdc
  • Recording Time: 1 sec to 15 mos
  • Sampling Rate: 1 sec, 10 sec, 1 min, and 30 min
  • Data Storage: 21,600 data points
  • Security Code: 4-digit combinations
  • Memory and Time Storage: > 5 years
  • Data Display: Concentration in mg/m3 and TWA, MAX, MIN, STEL, Date, and Time
  • Digital Output: RS-232
  • Operating Temperature: 14 to 122 F (-10 to 50 C)
  • Storage Temperature: -4 to 158 F (-20 to 70 C)
  • Power: Rechargeable lead-acid and interchangable battery
  • Operating Time: ≥ 24 hrs on battery; continuous on AC
  • Charging Time: Approx. 22 hrs
  • Dimensions (case): 14 x 6 x 10 in (35.6 x 15.2 x 25.4 cm)
  • Weight: 10 lbs (4.5 kg)

 

Tampilkan Lebih Banyak
Kontak Kami