Back to Top

1
Hi, Guest!
  • HI99151 Portable pH Meter for Beer Analysis

HI99151 Portable PH Meter For Beer Analysis

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail HI99151 Portable PH Meter For Beer Analysis

The Hanna Instruments HI99151 is a durable, waterproof, and portable pH and temperature meter designed specifically for beer analysis. Automatic calibration is performed at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature variations. The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions. The HI99151 uses the FC214D titanium body, amplified pH electrode that offers numerous features that improve pH testing for beer analysis. In the brewing process, the enzymes required to convert the starch into sugar are pH-sensitive with an optimal pH range between 5.2 pH and 5.6 pH. Different compounds are used to adjust the pH including phosphoric acid, lactic acid, and gypsum. Wort clarity and break formation are also affected by pH. Protein coagulation occurs during wort boiling, where the optimum pH is around 4.9, even though a common boil pH is 5.2. A pH that is too high will not only inhibit coagulation but also promote browning due to the interaction of amino acids and reducing sugars. Hop utilization during the wort boil is also affected by pH. As pH increases, the solubility of hop resins increases. Unfortunately for hop lovers, a high pH also increases the release of tannins resulting in a harsher taste. Higher pH also favors elevated microbial activity. As a living catalyst, yeast maintains a pH around 6.5 within its cells; however, the preference is to inhabit a more acidic environment. During the fermentation stage, the pH should be lower to accommodate the yeast and also to ensure microbial stability and consistent flavoring of the beer; an optimal pH range during fermentation is between pH 4.1 and 4.3. The HI99151 uses the FC214D amplified pH electrode with titanium body. This specialized electrode offers numerous features that improve pH testing in beer. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The probe’ s spheric sensing tip has a wide surface area for measurement in aqueous solutions. An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being measured. The ions provide for an electrical connection between the reference electrode and the indicating electrode. Any clogging of the reference junction will prevent the circuit from being completed and will result in readings that are erratic and/ or constantly drifting. A typical pH electrode has a junction made of ceramic material. This ceramic material can be easily clogged by samples such as mash, which has a high solids content, or wort, which is viscous. With the cloth junction of the FC214D it is possible to clear any obstruction by simply extracting 1/ 8” of the junction from the electrode. This exposes a new, renewed portion.
Tampilkan Lebih Banyak
Kontak Kami