Back to Top

1
Hi, Guest!
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.
  • KYORITSU 2300R

KYORITSU 2300R

Update Terakhir
:
04 / 03 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail KYORITSU 2300R

KYORITSU 2300R Keterangan • True RMS reading is an essential feature for accurate measurement. • “ Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal. • Set the DC current range to zero in one touch with the Zero Adjust function. • Auto Power Off. • Data Hold ( AC A / DC A only) . • Designed to international safety standard IEC 61010-1 CAT.III 300V. KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter. When load current is not affected by the distortion, both averaging value type and true RMS ( root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc..., averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices. Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves ( 50/ 60Hz) . The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms. ( Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.) Range : Current Measurement : AC A 0 to 100.0A DC A 0 to ± 100.0A ( Measuring Range) | ± 2.0% rdg± 5dgt ( 50/ 60Hz) | ± 2.0% rdg± 5dgt ( Accuracy) Conductor Size : Max Ø 10mm ( Measuring Range) Non Contact Voltage : Detect AC voltage without contacting with socket wire ( Measuring Range) During voltage detection, " Hi " flashes and a buzzer sounds intermittently ( Accuracy) Dimensions : 161.3( L) × 40.2( W) × 30.3( D) mm Crest Factor : 2.5 Weight : 110g ( with batteries) Maximum Digit : 1, 049 Safety Standard : IEC 61010-1 CAT.III 300V Pollution Degree 2 Power Source : R03 ( AAA) × 2 Accessories : Carrying Case R03 ( AAA) × 2 Instruction Manual
Tampilkan Lebih Banyak
Kontak Kami