Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan
untuk keterangan lebih lanjut.
- KYORITSU KEW MATE 2001, Digital Multimeters
KYORITSU KEW MATE 2001, Digital Multimeters
Update Terakhir
:
04 / 03 / 2024
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com
Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.
Detail KYORITSU KEW MATE 2001, Digital Multimeters
Model : KEW MATE 2001
• Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
• Sleep function to save battery consumption.
• Designed to international safety standard IEC 61010-1 CAT.III 300V
Range Measuring Range Accuracy
DC A 100A : 0~ 100A | ± 2% rdg± 5dgt
AC A 100A : 0~ 100A | ± 2% rdg± 5dgt ( 50/ 60Hz)
DC V 340mV
3.4V
34V
340V
600V : 0~ 600V
( 5 Autoranging) | ± 1.5% rdg± 4dgt
AC V 3.4V
34V
340V
600V : 0~ 600V
( 4 Autoranging) | ± 1.5% rdg± 5dgt
( 50~ 400Hz)
Resistance
( © ) 340©
( Continuity)
3.4k©
34k©
340k©
3.4M©
34M© : 0~ 33.99M©
( 6 Autoranging)
Buzzer sounds at 30© | ± 10© | ± 1% rdg± 3dgt
( ± 5% rdg± 5dgt)
( ± 15% rdg± 5dgt)
Frequency
( Hz) AC A 3.4kHz
10kHz : 0~ 10kHz
( 2 Autoranging) | ± 0.1% rdg± 1dgt
AC V 3.4kHz
34kHz
300kHz : 0~ 300kHz
( 3 Autoranging) | ± 0.1% rdg± 1dgt
Maximum AC/ DC
Circuit Voltage : 600V AC/ DC ( between line/ neutral)
300V AC/ DC ( against earth)
Conductor Size : Ø 10mm max.
Withstand Voltage : 3700V AC for 1 minute
Safety Standard : IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61010-2-032
IEC 61326-1
Power Source : Two R03 or equivalent ( DC1.5V) batteries
Dimensions : 128( L) × 91( W) × 27( D) mm
Weight : 220g approx.
Accessories : R03( 1.5V) × 2
Instruction Manual
Optional Soft Case
Tampilkan Lebih Banyak