Detail Mitech Ultrasonic Flaw Detector MFD350B

1 Introduction
The MFD350B is an advanced digital ultrasonic flaw detector featuring a multi-color TFT LCD and a host of new features to meet challenging inspection requirements. It combines powerful flaw detection and measurement capabilities, extensive data storage, and the ability to transfer detailed inspection data to the PC via its high-speed USB port.
The instrument incorporates many advanced signal processing features including a 10MHz RF bandwidth to permit testing of thin materials, narrowband filters to improve signal to noise in high gain applications, a spike pulser for applications requiring higher frequencies, and a tunable square wave pulser to optimize penetration on thick or highly attenuating materials.
The instrument can be widely used in locating and sizing hidden cracks, voids, disbands, and similar discontinuities in welds, forgings, billets, axles, shafts, tanks and pressure vessels, turbines, and structural components.
2 Specifications
l Range: 0 to 6000 mm, at steel velocity
l Material Velocity: 1000 to 9999m/ s
l Display Delay: -20 to 3400 µ s
l Probe Delay/ Zero Offset : 0 to 99.99µ s
l Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
l Test Modes: Pulse echo, dual element and thru-transmission
l Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
l Pulse Energy: Low, Medium and High spike pulse.
l Damping: 100, 200, 400 ohms
l Bandwidth ( amplifier bandpass ) : 0.5 to 10 MHz
l Gate Monitors: Two independent gates controllable over entire sweep range
l Rectification: Positive halfwave, negative halfwave, fullwave, RF
l System Linearity: Horizontal: + / -0.2% FSW, Vertical: 0.25% FSH, Amplifier Accuracy + / -1 dB.
l Reject ( suppression) : 0 to 80% full screen height
l Units: Inch or millimeter
l Transducer Connections: BNC or LEMO
l Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
l Dimensions: 263H× 170W× 61D mm
l Operating Temperature: -10 to 50 
l Storage Temperature: -30 to 50
 
 
Tampilkan Lebih Banyak