PERKIN ELMER LPC 500 Liquid Particle Counter

Update Terakhir
:
17 / 04 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail PERKIN ELMER LPC 500 Liquid Particle Counter

Alat Laboratorium Mikrobiologi

Deskripsi produk
LPC 500 Liquid Particle Counter

The LPC 500™ Liquid Particle Counter is a single particle optical sizing (SPOS) system designed to count and size particles individually with high resolution. When used for in-service oil samples, only 4 mL of 10x diluted samples are typically needed, offering reproducible results between high- and low-viscosity samples, while also minimizing washout requirements and solvent waste. The LPC 500:

Integrates seamlessly with ICP-OES for elemental analysis
Provides sample-to-sample analysis time of ~45 seconds
Uses less than 1 mL of lubricant sample per analysis
Boasts the smallest footprint of any standalone automated particle counter
Part Number N0810904

Overview

The LPC 500 Liquid Particle Counter consists of three components – an optical sensor, a multi-channel pulse analyzer (MPA), and a software controller – and is available in two configurations:

A patent-pending option coupling the LPC 500 counter with the Avio® 550 Max ICP-OES Oils system, enabling the same diluted sample to be analyzed for both wear metals and particle counting/sizing, so two analyses in a single run. Plus, all features and data outputs for the LPC 500 system have been integrated into Syngistix™ for ICP software, leveraging one software platform for both analyses.
A standalone LPC 500 for particle counting only which offers sample-to-sample analysis times of 95 seconds, with the same reduced sample size and sample preparation. This option is controlled by a separate software package that allows extensive customizability of the particle counting parameters.

Specifications
Depth
47.0 cm
Height
19.0 cm
Weight
8.5 kg
Width
37.0 cm
Application Note
A Novel Approach to Analysis of In-Service Lubricants for Particle Size/Count and Metal Content

Particle counting is becoming a more routine tool for lubricant condition monitoring and maintenance programs to better identify particles of certain sizes and concentrations that can contribute to machine failure. In-service oils and other lubricants are monitored for particle size similarly to how they are monitored for elemental concentration. An increase in the ISO code (ISO 4406) for particle count or concentration of key wear metals indicates when maintenance is required.

By adding the LPC 500™ liquid particle counter in-line with the Avio® 550 Max ICP-OES Oils system, lubricant samples can be analyzed for both wear metals and particles all in one run with results repeatably within one ISO code for the >4, >6 µm sizes for transmission and gear oil. Throughput of 45 seconds on average per sample with less than 1 mL is achieved for both ICP as well as particle counting and sizing, all with the smallest automated particle counting system in the lubricants testing industry.

Download this application note to learn more.


PDF 187 KB
Brochure
LPC 500-Avio 500 Combined Particle Count & Elemental Analysis of In-Service Lubricants - Interactive Brochure

For in-service oil testing labs challenged with fast turnaround and analytical accuracy, while also controlling operating costs, the wait is over. The new LPC 500™ liquid particle counter coupled to the Avio® 500 ICP-OES Oils system enables the same diluted sample to be analyzed for both elements and particle count/size in a single run – a game changer in laboratory workflow that considerably improves operating costs.

Two analyses, one run – with single sample preparation
Sample-to-sample analysis in 45 seconds
Uses less than 1 mL of lubricant sample per analysis
Generates less waste for the laboratory



PDF 1 MB
Case Study
CAT Dealer Improves Workflow Thanks to PerkinElmer’s LPC 500 Liquid Particle Counter

Read this case study to learn how a Caterpillar dealer, with 39 years of experience in the lubricants industry, improved test result accuracy and increased turn-around time by introducing a new high-performance liquid particle counter - the PerkinElmer LPC 500™ - to combine the power of particle count technology with elemental analysis, all in a single run. The game-changing LPC 500 provides sample throughput of approximately 45 seconds per sample with less than 1 mL of sample used for diluted sample preparation, freeing up technicians to perform other tasks and eliminating any human inconsistency in processing samples manually.


PDF 651 KB
Flyer
In-Service Oil Testing Reimagined for the Labs of Tomorrow Ensemble Flyer

In-service oil and lubricant testing labs like yours are all faced with the same challenges – increasing throughput, improving accuracy, and controlling operating costs. What if there was a way to reach your goals while optimizing the laboratory’s workflow? Now there is. The new LPC 500™ liquid particle counter coupled with the proven Avio® 500 ICP-OES Oils system brings together two critical analyses – particle counting/sizing and wear metals – delivering the following benefits for your lab:

Two analyses, one run – with single sample preparation
Sample-to-sample analysis at an average of 45 seconds
Uses less than 1 mL of lubricant sample per analysis
Generates less waste for the laboratory

PDF 834 KB
Guide
LPC 500 Liquid Particle Counter - Preparing Your Lab for Hyphenated VersionPerkinElmer's LPC 500™ liquid particle counter, Teledyne CETAC Oils 7400 autosampler and Teledyne CETAC Particle Xpress sample introduction system comprise a complete set of accessories for particle analysis of lubricating oils. This is used in conjunction with wear metals analysis by ICP-OES, coupling to a PerkinElmer Avio® 500 Oils system. This document provides an overview of the pre-installation lab preparation considerations for this solution.
PDF 1 MB
LPC 500 Liquid Particle Counter - Preparing Your Lab for Standalone VersionPerkinElmer's LPC 500™ liquid particle counter, Teledyne CETAC Oils 7400 autosampler and the SPM 700 syringe module comprise a complete system for particle analysis of lubricating oils. This document provides an overview of the pre-installation lab preparation considerations for this product.
PDF 1 MB
Product Note
LPC 500 Liquid Particle Counter Product Note

PerkinElmer’s LPC 500 Liquid Particle Counter is a single particle optical sizing system designed to count and size particles individually with high resolution. When used for in-service oil samples, only 3 to 4 mL of 10x diluted samples are typically needed, offering reproducible results between high- and low-viscosity samples, while minimizing washout requirements and solvent waste.

Plus, when coupled with an Avio 500 ICP-OES Oils system, the integrated solution provides particle count and elemental analysis in one run with sample throughput at an average of 45 seconds per sample, using less Than 1 mL of lubricant per analysis.

Download the product note to learn more about the benefits of the LPC 500 Liquid Particle Counter.


PDF 866 KB
Regulatory Compliance Certification
Product Certificate - Liquid Particle Counter 500Product Certificate for the Liquid Particle Counter 500
PDF 554 KB

Hubungi :

Juni Tarigan (Mr.)

0811 198 0702


Pera (Ms.)

0811 3801 0819


Admin

0813-2310-201


PT. ANDALAN BANGUN SEJAHTERA

Jl. Sumur Batu No. 1, Kemayoran

Jakarta Pusat - Indonesia 10640

Telp : +6221-42803207, 4227517


Fax : +6221-4280320
Tampilkan Lebih Banyak
Kontak Kami