Back to Top

1
Hi, Guest!

Rapid Flash Tester Closed Cup Rapid Test

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit

Harga

CALL
Contact :
Marketing : Bpk Juni / 08111980702
Marketing : Ibu Pera / 085210207070
Telp : 021 - 42803207
Fax : 021 - 42803208
email : sales@andalanbangun.com

Suplier alat-alat laboratorium & Intrument untuk berbagai keperluan alat-alat laboratorium Microbiology, Chemical and Reagent, Equipment, Medical dan Glassware.

Detail Rapid Flash Tester Closed Cup Rapid Test

Rapid Flash Tester Closed Cup

K16500 Rapid flash tester, closed cup aluliminium test cup/brass lid & shutter 115v 60hz 

K16591 Rapid flash tester, closed cup aluliminium test cup/brass lid & shutter 220-240v 50/60hz

K16502 Rapid flash tester, closed cup aluliminium test cup/brass lid & shutter 115v 60hz

K16542 Rapid flash tester, closed cup aluliminium test cup/brass lid & shutter 220-240v 50/60hz

Verifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C.

  • Conforms to ASTM D3278, D3828; DOT CFR 49-173.115; IATA;
  • ISO 9038, BS3900 Part A11, A13, A14 and related specifications
  • One minute test with a 2mL sample
  • Simple to operateRapid Tester® provides rapid determinations of flash point or sustained burning qualities by using a small sample. A flash/no flash test result is achieved in one minute for flash points below 212°F (100°C) with a 2mL sample. Ideally suited for quality assurance and environmental compliance testing as well as actual flash point for paints, fragrances, hydrocarbons and other liquids. Open cup models are used for determining sustained burning qualities characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics. Features convenient semi-automatic operation for flash/no flash tests. Set the test temperature on the digital display and inject a 2mL or 4mL sample into the sample cup. The tester quickly stabilizes itself at the desired value, permitting the test flame to be applied and the result to be observed by the operator. Unit also performs conventional determinations of actual flash temperature by the small scale closed tester method. The Closed Cup Model is for routine flash point tests in the range from –30 to +300°C (–22 to +572°F).
  • Thermometer, range 32 to 572°F (0 to 300°C)
  • SyringeConforms to the specifications of: ASTM D3278, D3828; IP 303; ISO 3679, ISO 3680, ISO 9038; DOT CFR 49-173.115; IATA115V 60Hz
    220-240V 50/60Hz

    lxwxh,in.(cm): 15x23.4x6.3 (38.1x8.6x16.2)

    Net Weight: 11 lbs (5.0 kg)

    Shipping Weight: 14 lbs (6.4 kg)

    Dimensions: 24x10x7in (61.0x25.4x17.8 cm)

  • K16506 Fuel Cylinder Valve
  • K16507 Heat Transfer Compound for thermometer
  • K16508 Metal Cooling Block to facilitate cooling of the sample cup between tests
  • K16509 Refrigerant Charged Cooling Block to hold cooling mixture for subambient testing
  • K16510 Syringe 2mL/4mL
  • K16511 Thermometer, range 32 to 572°F/0 to 300°C
  • K16512 Thermometer, range 32 to 230°F
  • K16513 Thermometer, range 212 to 572°F
  • K16514 Thermometer, range 0 to 110°C
  • K16515 Thermometer, range 100 to 300°C
  • K16516 Thermometer, range –36 to +105°F
  • K16517 Thermometer, range –38 to +40°C
Tampilkan Lebih Banyak
Kontak Kami