Detail KYORITSU Digital Multimeters KEW 1052

Alat Laboratorium Mikrobiologi

Deskripsi produk
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.

Detection mode
MEAN/RMS (switch)
DC V
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS]
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
AC V [MEAN]
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A
600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS]
600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer
600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test
2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance
10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency
10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature
-50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions
Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source
R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions
192(L)×90(W)×49(D) mm
Weight
Approx. 560g (including batteries)
Included Accessories
7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
Option
Description
Model
Specification
Crocodile clip test lead
7234
CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor
8115
AC 130A / DC 180A
Clamp sensor
8121
AC 100A
8122
AC 500A
8123
AC 1000A
8146
AC 30A
8147
AC 70A
8148
AC 100A
Banana Ø4mm Adjuster Plug
7146
length:190mm
USB Communication set
8241
USB adaptor + USB cable + DMM Software
Carrying case
9154
for the main unit with testi leads and communication cable
Thermocouple Type K Specification
Description
Model
Specification
Temperature probes
8405
-40ºC - 500ºC
(Surface type, Point material: Ceramic)
8406
-40ºC - 500ºC (Surface type)
8407
-40ºC - 700ºC (Liquid, Semi-solid)
8408
-40ºC - 600ºC (Air, Gas)